Your cart is empty!
This replacement screw maintains the clamping mechanism of the Murdoch eye speculum used during anterior segment surgery. The precise fit and stainless steel construction ensure reliable, lasting performance across multiple reprocessing cycles. Replacement capability extends the useful life of the parent speculum.
Features & Benefits
This replacement screw fits Cook speculum size #2 and is constructed for reliable instrument retention. Its corrosion-resistant stainless-steel design supports repeated clinical use and secure frame adjustment.
This replacement screw is engineered for Cook speculum size #1, providing secure tightening and reliable thread engagement. Stainless-steel construction ensures durability and consistent performance during repeated sterilization cycles.
Sold as a replacement length for Kratz‑Barraquer aspirating speculums (item codes 11‑2‑6282 and 11‑2‑6286), this 1000mm silicone tubing restores the suction path between speculum and vacuum source. The flexible silicone wall keeps kinking at bay across the drape and resists collapse under steady vacuum. Reusable handling supports routine reprocessing alongside the parent instrument.
Extended 10‑foot silicone replacement tubing for Simcoe cannula systems. Longer length accommodates layouts where the infusion bag or pump sits at greater distance from the surgical field.
Replacement silicone tubing for Simcoe cannula systems. Compatible with standard connections on both Simcoe (5‑5082) and standard anterior chamber cannulas.
Designed for retinal and posterior segment procedures, this 0.5 × 0.17 × 6mm diamond knife enables controlled scleral incisions with minimal tissue trauma. The straight 20‑degree angle and extended 6mm blade length support safe access to posterior structures. J‑slot bayonet mounting preserves visual axis alignment during delicate retinal work.
This reusable blue bipolar cord connects electrosurgical generators to bipolar forceps via banana pin connectors, supporting consistent energy delivery across repeated cases. The Santoprene 8271-75 insulation preserves signal integrity over the full 3.66m length, while the angled instrument end allows simplified cable routing in confined instrument trays. Non-sterile packaging permits cost-effective sterilization within your facility.
This reusable blue bipolar cord connects bipolar forceps to the generator with a straight instrument end, sized for routine electrosurgical setup. The reusable format reduces single‑use consumable load, and the non‑sterile delivery suits in‑hospital reprocessing workflows.
This reusable irrigating cystotome is formed with a gentle curve to improve approach angles during capsulorhexis. The 25ga tubing permits micro-volume irrigation, while the 3mm straight segment followed by a 13mm bend-to-tip arc allows intuitive capsular entrance without excessive manipulation.
This reusable stainless steel wrench facilitates safe assembly and disassembly of detachable microscope handpiece tips and optical couplers. Precision‑machined design accommodates standard microsurgical handpiece connection geometries without marring optical surfaces. Compact, robust construction withstands repeated use across case‑to‑case turnaround cycles. The wrench enables quick instrument setup without cross‑contamination of sterile working surfaces.
This reversed Sinskey iris IOL hook brings a 0.2mm reverse hook tip to DSAEK procedures where fine IOL positioning and iris manipulation demand micron-level control. The 12mm bend-to-tip geometry supports reach beneath the iris, while the polished round handle enables tactile rotation and withdrawal of the lens.
This reversed Sinskey iris/IOL hook uses a 0.2mm reverse‑curved tip designed to engage haptics or iris tissue atraumatically. The 12mm bend‑to‑tip geometry improves approach angles within the capsular bag, while the polished round handle provides smooth rotational feel during micro‑adjustments.
This reversed Sinskey hook variant maintains the same 0.2mm reverse tip and 12mm bend‑to‑tip distance but incorporates a polished round handle optimized for consistent glide and low‑resistance manipulation during IOL positioning.
These Rich corneal transplant scissors feature left‑curved extra‑delicate blades designed for fine lamellar tissue contouring. The three‑hole handle enhances fingertip precision during controlled corneal graft dissection.
These Rich corneal transplant scissors feature extra‑delicate right‑curved blades engineered for fine lamellar graft contouring. The three‑hole handle delivers stable fingertip control during microsurgical incisions.
This Rizzuti double‑ended instrument combines lens expressor and iris retractor functions in a single 146mm platform. The 3mm wide muscle hook tip serves dual role: gentle iris traction during capsulotomy, and lens nucleus expression during delivery. The malleable shaft permits fine anatomic adaptation while the polished stainless steel finish supports reliable performance across cases.
The Rizzuti superior rectus forceps is designed for extraocular muscle isolation and grasping during horizontal and vertical strabismus surgery. Its 45-degree angled shafts position the tips perpendicular to the muscle insertion, while the 1 × 2 interlocking teeth secure firm hold without crushing delicate muscle tissue. The serrated cross-action handle supports controlled advancement.
Delicately pointed tips give these Rolf utility forceps a fine grasp on suture, drape edges, and small ophthalmic accessories at the field. The straight shaft and 108mm overall length keep the working tip clear of the surgeon's hand during precision handoffs. Light spring tension supports prolonged microsurgical use without finger fatigue.
This roller expressor forceps is designed for meibomian gland expression, delivering controlled mechanical pressure to clogged lipid glands along the eyelid margin. The straight stainless‑steel construction and roller tip geometry reduce tissue trauma while ensuring consistent expulsion of inspissated meibum. At 111mm overall length, the instrument provides comfortable reach and leverage for bilateral eyelid assessment.
This Rosen‑style phaco splitter carries a 60‑degree angled tip with a 10mm tip-to-bend distance, supporting controlled approach to the nucleus through standard phaco incisions. The knurled handle improves tactile grip during chop execution, and the 110mm overall length keeps the working tip well-balanced in the anterior chamber.
This Rosen-style phaco splitter features a 90-degree angled tip designed for nucleus division during phacoemulsification. The knurled handle enhances grip precision, and the 10mm tip-to-bend distance provides stable approach geometry within the anterior chamber.
The Rosen-style titanium phaco splitter delivers controlled nucleus fracturing through its 10mm tip-to-bend distance and straight-shaft design. The round grooved handle provides superior grip control during the critical splitting phase of phacoemulsification. Titanium construction ensures durable performance and corrosion resistance across repeat sterilization cycles.
The Rosenwasser (Melles) DSAEK stripper is engineered for precise separation and insertion of donor corneal grafts during Descemet's-stripping endothelial keratoplasty procedures. Its angled shaft with 11mm bend to tip and forward 90-degree orientation positions the sandblasted tip optimally within the anterior chamber while protecting the endothelial graft. The round knurled handle and 125mm length ensure stable graft manipulation.
This Rosenwasser DLEK lamellar donor shovel incorporates a 4mm wide plate with raised retaining rims on two sides for controlled lamellar graft support. The rounded profile distributes tissue contact evenly, while the 121mm length allows steady approach during donor handling in DLEK procedures.
These Rosenwasser donor lamella inserting forceps incorporate thin vaulted 12mm shafts for optimal lamellar placement. The three‑hole handle enhances micro‑control during donor tissue insertion.
DSAEK and DMEK donor tissue insertion require precision and atraumatic handling, which the Rosenwasser donor lamella inserting shovel provides. Its 5mm wide platform with retaining rim on three sides secures and guides the donor disc into the anterior chamber. Stainless steel construction ensures rigidity during careful lamellar Descemet's insertion.
This Rosenwasser endothelial stripper features a 45-degree angled semi-sharp tip for delicate endothelial scraping during PLK procedures. The round stainless-steel handle provides balanced tactile feedback, and the 5-inch (127mm) length supports ergonomic micro-access.
This Rosenwasser endothelial stripper, also known as a Melles PLK scraper, features a 90-degree angled semi-sharp tip for controlled endothelial layer separation. The angled shaft improves approach geometry, while the round stainless-steel handle supports steady microsurgical control.
The Rosenwasser DALK Cannula is engineered for deep anterior lamellar keratoplasty procedures requiring precise controlled dissection in the stromal plane. Its 27ga gauge provides fine cannular access while the top beveled spear-shaped tip enables controlled separation and hydrodissection along the stromal-epithelial interface. The 0.2mm bottom port delivers targeted fluid flow for stroma-specific dissection while minimizing endothelial trauma.