Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
Tipped with a silicone squeegee, this 27ga capsule polisher sweeps residual cortex and lens epithelial cells from the posterior capsule without abrasive contact. The fine gauge allows passage through a side‑port incision, and the soft polymer surface follows the capsular curve for atraumatic cleanup.
Features & Benefits
Formed at a 27ga lumen, this irrigating cystotome combines a pre‑shaped cutting tip with a through‑lumen for simultaneous capsulotomy initiation and balanced irrigation. The 16mm working length suits standard phaco incisions, and the formed tip provides a defined cutting angle for consistent capsular flap starts.
A formed 25ga cutting tip on this irrigating cystotome initiates the anterior capsulotomy while the through‑lumen delivers balanced irrigation to maintain chamber depth. The 16mm working length fits standard phaco approaches, and the pre‑shaped tip provides a consistent cutting angle for predictable capsular flap starts.
The Chang hydrodissection cannula uses a 27ga shaft to deliver a focused fluid wave between the anterior capsule and lens cortex. The fine gauge concentrates the stream at the cortex‑capsule interface, helping the surgeon mobilize the nucleus efficiently during phacoemulsification.
A 23ga irrigating cystotome with a formed tip on a 5/8 inch shaft, this disposable scores and tears the anterior capsule while balanced salt solution maintains chamber depth. The pre‑formed bend presents the cutting edge to the capsule at a consistent angle, supporting reproducible tear initiation. The 23ga lumen sustains steady flow throughout capsulotomy.
This 27ga anterior chamber cannula offers a 9mm bend for moderate‑depth irrigation and viscoelastic placement under clear‑corneal incisions. The fine lumen produces low‑turbulence flow well suited to chamber maintenance during phaco or IOL work. The slender shaft preserves wound architecture during repeated entries.
A 27ga lumen and 5mm bend‑to‑tip define this anterior chamber cannula, placing the outlet just beyond the wound for short‑reach irrigation and viscoelastic placement. The fine gauge preserves a low‑turbulence stream during careful chamber work.
Atkinson's 23ga retrobulbar needle delivers anesthetic to the muscle cone with a 1‑1/2" trajectory and a tip profile tuned for atraumatic passage. The intermediate gauge balances flow with structural rigidity, giving the operator a stable directional track during block placement.
Designed by Atkinson for retrobulbar block placement, this 25ga needle reaches the muscle cone through a 1‑1/2" trajectory while maintaining stable directional control. The fine gauge supports a smooth tissue track, and the tip profile is tuned for controlled deposition of anesthetic.
A 30ga lumen with a 9mm bend‑to‑tip equips this anterior chamber cannula for fine fluid delivery deeper into the chamber. The longer bend reaches toward the angle and behind the iris while preserving the gentle flow characteristics of the micro‑gauge.
Designed for corneal stromal puncture in recurrent erosion treatment, this 25ga needle on a 1 inch shaft creates micro‑perforations through the basement membrane to promote durable epithelial adhesion. The fine gauge produces controlled punctures without disrupting surrounding stroma. Single‑use packaging keeps the tip sharp for each treatment.
Rycroft air injection cannulas deliver controlled boluses of air or fluid into the anterior chamber through a 30 gauge tip angled 45 degrees, with 5mm from bend to tip. The short angled shaft directs flow under the iris or against the corneal endothelium during DSAEK bubble formation and chamber reformation. A standard luer hub mounts to most ophthalmic syringes.
An Atkinson peribulbar needle in 25ga with a 7/8 inch shaft, this disposable supports shallow peribulbar anesthetic placement with a finer gauge than the 23ga model. The rounded bevel geometry limits vascular trauma while maintaining controlled tactile feedback. The shorter shaft suits anterior orbital work.
This silicone‑tip capsule polisher (squeegee) combines gentle tissue contact with efficient epithelial removal following cataract extraction. The 27 gauge fine bore minimizes incision trauma while the silicone end confers atraumatic gliding across the anterior capsule. The blue cartridge format supports efficient sterile field management in high‑volume cataract workflows.
This 27ga anterior chamber cannula features a 7mm bend‑to‑tip, placing the irrigation outlet near the mid‑chamber for general fluidics work during cataract surgery. The fine gauge maintains low‑turbulence flow, and the moderate bend supports a clean approach beneath the corneal incision.
With an 8mm bend‑to‑tip on a 27ga shaft, this anterior chamber cannula extends reach across the chamber for irrigation and viscoelastic management. The fine gauge keeps flow gentle around the iris and endothelium during extended manipulation beneath the corneal incision.
Angled at 55 degrees on a 25ga, 5/8 inch shaft, this irrigating cystotome offers an aggressive bend for capsular access through tighter corneal incisions. The 55 degree tip presents the cystotome sharply against the anterior capsule, helping initiate and direct the tear during cataract preparation. The intermediate gauge maintains chamber depth via balanced salt solution flow.
This micro J‑shape cannula delivers a 25ga lumen on a slender J hook measuring 85 × 1.7mm, narrow enough to slip through tight side ports yet long enough to reach across the chamber. The hooked tip directs irrigation behind the iris or under the iris plane during cataract work. The low‑profile shaft preserves wound integrity.
Built around a 27ga lumen with a 4mm bend‑to‑tip, this anterior chamber cannula supports short‑reach irrigation and wound hydration just beyond the corneal incision. The fine gauge preserves low‑turbulence flow during routine fluidics tasks at the close of cataract surgery.
Sized at 25ga with an 8mm working segment, this hydrodissection cannula directs a focused fluid wave between the anterior capsule and lens cortex. The shorter working length suits surgeons who prefer a controlled, near‑incision approach to cortical cleaving rather than deeper sub‑capsular reach.
This 1mm angled sideport knife creates the small secondary paracentesis used for second‑instrument access during cataract surgery. The narrow blade produces a tight self‑sealing wound just wide enough for a chopper or hook, preserving chamber stability while a second tool enters. Individually sterile packaging with six per box.
Designed for compatibility with the Clarity MSI RetCam imaging system, this MacKeen premature infant self‑retaining retractor uses 3mm and 5mm round nesting blades to provide minimal‑profile lid retraction in neonatal eyes. The 40mm frame keeps the camera path unobstructed during ROP screening.
Equipped with a silicone squeegee tip, this 23ga capsule polisher sweeps residual cortex and lens epithelial cells from the posterior capsule without abrasive contact. The slightly larger gauge supports irrigation alongside polishing, and the soft polymer surface follows the capsular curve for atraumatic cleanup.
Carrying a 25ga lumen with a short 4mm bend‑to‑tip, this anterior chamber cannula is built for near‑incision irrigation and wound hydration after phacoemulsification. The intermediate gauge balances flow with atraumatic passage through small corneal wounds.
Carrying a 30ga lumen with a short 4mm bend‑to‑tip, this anterior chamber cannula is sized for delicate, near‑incision fluid delivery. The micro‑gauge minimizes turbulence around the corneal endothelium during careful chamber adjustment or wound hydration.
This 30ga anterior chamber cannula carries a 7mm bend‑to‑tip, sized for delicate mid‑chamber irrigation and viscoelastic management. The micro‑gauge keeps turbulence low near the iris and endothelium, and the moderate bend places the outlet within easy reach of the central chamber.
A replacement 3.5mm round diamond burr in medium grit for the Algerbrush II chuck. The diamond surface removes corneal rust rings and superficial epithelial debris more aggressively than a carbide burr, suited to larger or more adherent rust deposits.
The Koch stop-chop manipulator presents a 90‑degree angled tip with a 1.5mm working length and 10mm bend-to-tip distance, supporting the stop-and-chop sequence during phacoemulsification. The round knurled handle improves tactile grip during groove sculpting and subsequent chop engagement, with 112mm overall length balancing reach and control.
The 23ga curved anterior chamber cannula delivers slightly higher flow irrigation than finer micro‑gauges while preserving controlled entry geometry. Its standard curve and 22mm shaft reach across the anterior chamber for viscoelastic delivery and chamber maintenance during cataract surgery. Slim stainless tubing holds shape through repeated angling.
With a 19ga lumen and a 10mm bend‑to‑tip, this anterior chamber cannula combines high‑flow capability with extended intraocular reach. The larger gauge supports rapid chamber reformation or robust viscoelastic delivery, and the longer bend gives the outlet a deeper trajectory toward the angle.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.