Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
This Abraham 66D magnifying YAG laser lens combines image magnification (1.8x) with laser magnification (56x) for precise Nd:YAG capsulotomy. The 15.5mm contact diameter and 16.5mm lens height provide stable contact alignment while supporting controlled posterior capsule ablation and corneal safety.
Features & Benefits
The Akahoshi nucleus sustainer delivers gentle nuclear fragment support and positioning during phacoemulsification with its elongated paddle-shaped blade. The right-side dish-out geometry and angled 10mm bend-to-tip profile enhance nuclear manipulation while reducing capsular trauma. The round knurled handle provides secure fingerhold during extended fragmentation and removal sequences.
The Barraquer tonometer (15‑21 mmHg range) is designed for rapid, non‑contact intraocular pressure measurement during phacoemulsification. The phaco slip grip allows single‑handed measurement without removing the hand from the operative field. Its compact, lightweight design supports frequent pressure checks throughout the cataract procedure.
The Belz lacrimal sac rongeur is engineered for delicate bone and tissue removal during dacryocystorhinostomy and lacrimal sac procedures. Its rounded 17mm jaws, tapered to 2mm at the tip and 3mm at the midline, provide controlled biting leverage while the dull finish minimizes inadvertent soft-tissue trauma. The 180mm length supports stable handheld control and access to deep lacrimal anatomy.
Berens muscle clamps are engineered for controlled grasping and fixation of extraocular muscles during strabismus surgery. The 13.5mm angled adjustable blades accommodate varying muscle diameters, while interlocking teeth in the lower jaw secure the muscle against the upper jaw grooves. A round knurled handle provides stable control.
Bishop-Harmon tendon tuckers facilitate controlled plication of extraocular muscles during strabismus procedures. The triangular-shaped tips engage muscle tissue with precision, while surface markings indicate standard 5mm and 10mm tuck depths. A round knurled handle supports secure grip during delicate muscle work.
This blunt 14 gauge × 20mm needle provides safe anterior chamber access without corneal perforation risk during ophthalmic procedures. The straight shaft enables controlled fluid injection with minimal trauma to chamber structures.
An angled working tip distinguishes this Brierley nucleus splitter, supporting controlled bisection of the cataractous lens during phacoemulsification. The single-ended knurled handle provides tactile grip stability during chop execution.
The Bruder rectangular expressor delivers targeted pressure to obstructed meibomian glands through its flat, broad paddle tip. This geometry distributes force across the lid margin without focal tissue trauma, facilitating consistent lipid clearance in dry eye disease management. The 111mm stainless‑steel design supports durable clinical use across repeat cases.
The Carter sphere introducer is used during enucleation and evisceration to seat an orbital implant into the posterior socket without direct finger contact. The 125mm shaft cradles the sphere and delivers it through the conjunctival opening, helping the surgeon center the implant before Tenon's closure.
This 2.8mm spear diamond knife with a 90 degree angle provides wide, perpendicular entry for clear corneal cataract incisions on a black gold titanium handle. The 2.8 × 6 × 0.17mm black CVD blade delivers consistently sharp wound profiles across repeat uses, with J‑slot bayonet geometry enabling precise positioning.
This angled diamond knife brings precision to corneal and limbal incisions in cataract and refractive surgery. Diamond edge construction delivers lasting sharpness and reproducible incision geometry. The titanium‑mounted blade combines rigidity with corrosion resistance over repeated clinical use.
The Crawford intubation set is configured for lacrimal canalicular and nasolacrimal duct intubation, providing the probes and guides needed to thread silicone tubing through the drainage system. Its 603mm overall length supports passage from punctum to nasal recovery. The set is reusable across cases with appropriate reprocessing.
The DK phaco wrench is a titanium-handled accessory tool designed for precise adjustment of Alcon phaco-handpiece needle-fitting connections during case setup and maintenance. Its round knurled titanium handle provides secure grip without slipping during needle-hub manipulation. The compact wrench geometry supports rapid handpiece setup while preserving the integrity of threaded connections.
The DSAEK roller features a titanium handle with precision bearing design to facilitate smooth, uniform graft positioning and adhesion during descemet stripping automated endothelial keratoplasty. The bearing surface minimizes graft trauma while providing tactile feedback for optimal graft seating. Titanium construction ensures rigidity and longevity in high‑use surgical environments.
This Freer lacrimal chisel features a curved 5mm‑wide blade, a serrated square handle, and a polished finish for controlled lacrimal tract sculpting. The geometry supports stable instrument orientation during delicate bone or tissue work.
The Girard anterior chamber needle set provides safe access for anterior chamber fluid management during cataract surgery. The 23g beveled blunt tip without hub and 7.5mm working length support atraumatic anterior chamber manipulation. The polished finish enables clear visualization throughout the procedure.
The Godfrey lens folder features a 45‑degree angled design with 0.8 × 0.3mm tips to support smooth IOL insertion during phacoemulsification. The 12.3mm shafts and flat titanium handle work together to minimize endothelial trauma while enabling predictable lens delivery.
The Hardy enucleator combines a curved right geometry with a 3.4mm blade to support controlled orbital enucleation. The 125mm working length extends into the deep orbit while the 241mm overall length provides a balanced reach for retrobulbar dissection. Stainless‑steel construction is built for reliable performance and lasting durability across repeat clinical use.
The Helveston scleral ruler delivers precision measurements for horizontal rectus recession and advancement distances during strabismus surgery. The angled vaulted tip with 15mm bend-to-tip geometry aligns with scleral contours, while 5mm notched increments enable consistent measurement intervals across the surgical field. Stainless steel construction supports lasting clinical durability.
The intracapsular ring injector combines a titanium body with a 0.3mm steel hook and plunger mechanism to precisely deliver PMMA or silicone rings into the capsular bag during corneal refractive surgery. The fine hook geometry supports safe ring placement without capsular trauma. Its 162mm length enables accessible capsular positioning.
This John DXEK/DSAEK Descemet stripper incorporates a strongly vaulted shaft with a 15mm bend‑to‑tip configuration for controlled posterior lamellar engagement. The working end supports precise stripping of Descemet membrane during endothelial keratoplasty.
The Karpecki debrider features a gently curved tip with bilateral sharp edges engineered for controlled removal of debris and epithelial disease from the eyelid margin. Its flat handle and precise 121mm length support stable two‑handed positioning during lid margin restoration. The stainless‑steel construction maintains edge sharpness across multiple sterilization cycles.
Keener lens-loop snare wires are replacement wires for the Keener nucleus divider, enabling multiple segmentation procedures per instrument set. Each pack includes three individually wrapped stainless-steel wires that maintain tensile strength across many cataract cases. Compatible with standard Keener divider frames.
The Knapp lens spoon with 5mm wide spoon-shaped tip and solid middle support provides atraumatic lens engagement and removal. The solid middle construction minimizes flexing during nuclear manipulation while the smooth spoon design protects posterior capsule.
This Kratz scratcher uses a 22ga sandblasted shaft with a short 20mm overall length for controlled anterior capsule scoring. The textured finish enhances friction at the working tip.
This lens injector is engineered for single‑hand plunger operation during phacoemulsification and IOL implantation with Acrysof acrylic lenses. The titanium construction provides lightweight rigidity compatible with all Monarch cartridge systems. The compact, ergonomic design supports controlled lens delivery with minimal hand fatigue during high‑volume cataract surgery.
The Maloney Keratometer is a titanium contact applanation gauge for real‑time intraoperative corneal curvature assessment. Its dual‑diameter design�10mm upper surface, 30mm lower contact base�allows stable single‑hand positioning against the cornea while the narrow profile minimizes visual field obstruction. At only 25mm in height, it provides repeatable readings for toric IOL alignment and refractive surgery verification.
Ring?tip geometry distinguishes the Nordan capsule elevator, distributing load across the lens capsule surface to reduce perforation risk during nuclear management. Its angled configuration supports subsurface elevation of nucleus or posterior capsule during phacoemulsification. The round handle supports secure yet sensitive control.
The O'Gawa lens dialer is engineered for controlled manipulation of intraocular lenses during implantation and alignment. Its angled shaft with collar-button tip allows fine rotational positioning of the IOL within the capsular bag. A round handle supports fingertip control during critical lens centering.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.