This Henderson pre‑operative reference marker uses a durable half‑circle geometry with blunt positioning pins at 0�, 90�, and 180�. The round knurled handle improves grip security during toric axis pre‑marking while minimizing rotational drift.
Features & Benefits
Designed for left‑hand use during right‑dominant phacoemulsification, this Nagahara phaco chopper carries a flat interior cutting edge that initiates clean nuclear fracture along the chopping axis. The shaft is angled 45 degrees with a 10mm bend‑to‑tip and a 1.5mm cutting edge oriented at 60 degrees, giving the surgeon a defined purchase point on the nucleus while clearing the capsular rim. A round knurled handle on the 114mm shaft keeps rotational control predictable through divide‑and‑conquer or stop‑and‑chop technique.
These titanium McPherson tying forceps are angled and include 5mm tying platforms for secure knot support. The three‑hole handle and 105mm overall length enhance rotational and axial control.
This Barraquer microsurgical needle holder is curved with delicate 8mm jaws and no locking mechanism for high‑precision suturing. The 133mm length and fine profile support controlled manipulation of micro‑sutures.
Designed for iris tissue handling during anterior segment surgery, these straight Graefe iris forceps feature fine serrated tips that grasp the iris margin without crushing. The 70mm compact length supports tactile control through limbal or paracentesis access. Polished stainless steel construction holds up to repeat sterilization cycles.
Used to outline the optical zone during refractive keratotomy and corneal procedures, the Bores O‑Z marker imprints a 6.5mm circular reference on the corneal epithelium. The smooth handle supports light, consistent contact pressure, and the 100mm overall length keeps the instrument well balanced over the eye. The straight shaft preserves a perpendicular approach to the corneal surface.
The small Jameson muscle hook engages extraocular muscle bellies during strabismus surgery. Its slim shaft and rounded tip slide beneath the muscle insertion to lift it clear of the sclera for measurement, recession, or resection. A grooved handle improves grip during the controlled lifting maneuver, and the 127mm length suits standard pediatric and adult strabismus exposure.
The curved iris forceps features delicate lightly curved tips with 1 × 2 mouse‑style tooth pattern optimized for gentle iris manipulation without trauma. The curved shaft geometry suits approach to the iris plane during anterior segment work. The fine tips and delicate construction minimize bleeding and tissue damage.
The titanium Castroviejo tying forceps in straight configuration features 7mm tying platform and refined geometry suited to clear visualization during IOL and corneal knot placement. The straight shafts enable unobstructed view of knot formation, and titanium construction offers enhanced durability. The broad platform ensures consistent tying force distribution.
The titanium Sheets‑McPherson tying forceps in 45‑degree angled configuration combines 10.5mm tying platform with reduced weight compared to stainless steel. The angled geometry provides ergonomic access during bimanual IOL and corneal surgery. Titanium construction offers corrosion resistance and enhanced durability over many sterilization cycles.
This modified Barraquer speculum opens the lids with 15mm solid blades shaped longer and 8mm deep for procedures needing extended palpebral exposure. The 26mm outside by 10mm inside spread holds the lids clear of the cornea while preserving working access through the aperture. A dull finish across the 43mm body reduces microscope glare during anterior segment cases.
The Shepard intraocular lens forceps fold and deliver foldable IOLs through small phaco incisions. A cross‑action design with 1.45 × 2mm serrated upper and lower jaws grips the optic securely without slippage, and a slide lock holds the lens compressed until release. The curved‑up shaft preserves the surgeon's view of the wound during insertion.
The Berkeley marker carries paired 3mm and 3.25mm reference rings on a single instrument, letting the surgeon choose between two closely spaced optical zone diameters during refractive marking. The smooth flat handle supports steady fingertip orientation through ink loading and contact. A 110mm body balances the dual‑ring head for clean impressions.
This double‑ended Berkeley marker provides both 4mm and 4.5mm corneal reference rings, enabling dynamic correction for variable astigmatism during IOL calculations and implantation. The smooth flat handle ensures precision marking without slipping. At 110mm, balanced length supports microscopic control and corneal contact stability.
The Snider-Castroviejo tying forceps incorporates a 0.12mm tip with 1 × 2 teeth, tying platforms, and a guide pin for controlled suture manipulation during ophthalmic knot formation. The three-hole handle geometry optimizes fingertip precision work, while the integrated tying platform reduces hand fatigue during repetitive knot tying at the limbus and cornea. Reusable stainless steel construction ensures consistent tactile feedback.
This Castroviejo caliper measures anterior segment dimensions with 1mm precision across a 0‑40mm range. The adjusting screw mechanism locks measurement values, enabling accurate documentation of corneal diameter, limbal location, and surgical reference zones. The straight 178mm length supports stable positioning during pre- and intraoperative assessment.
This angled titanium tying forceps with 45-degree inclination enables ergonomic suture manipulation in anterior segment closures. The 7mm working distance from bend to tip supports access to peripheral and paracental closure sites, while the 6mm platforms and flat square grip deliver reliable knot placement. Lightweight titanium construction ensures comfort during extended case sequences.
Designed for secure intraocular lens handling, these Freeman‑Jaffe forceps feature a longitudinal groove along the curved jaw that cradles the IOL haptic without compressing the optic. The standard curve clears the corneal incision while approaching the capsular bag, and the three‑hole handle keeps the 102mm instrument light in the fingertips throughout folding and delivery. Stainless steel construction holds geometry across repeated autoclave cycles.
This O'Gawa curved tying forceps variant features 5.5mm tying platforms with 0.3mm gap at platform heel, providing alternative curved configuration for ergonomic IOL and corneal knot placement. The curved shafts suit natural surgical positioning angles while the gap design minimizes suture trauma. Each variant supports efficient tying across routine cases.
The McPherson tying forceps features 7.5mm tying platforms�broad flat working surfaces that stabilize sutures during knot formation. The angled shaft at 105mm length positions the platforms optimally for wound closure at the cornea and limbus. Titanium construction provides rigidity and corrosion resistance through repeated sterilization cycles.
This Castroviejo needle holder features a tungsten carbide jaw construction built for reliable durability across repeat ophthalmic microsurgical cases. The straight geometry and locking mechanism provide secure needle purchase during fine corneal and anterior segment suturing. At 140mm overall length, it enables precise fingertip control for capsulorhexis closure and IOL fixation work.
The O'Gawa mini dialer delivers ultra-precise nucleus positioning in cataract extraction with its 0.25mm tip and angled 11mm working distance. Titanium construction provides lightweight control, while the round handle and 121mm overall length support sustained manipulation during phacoemulsification sequences. The tapered tip enables gentle nuclear fragmentation and repositioning within the capsular bag.
Configured for placement on the nasal side intraoperatively, this Barraquer speculum uses 14mm square‑wire blades and a 25mm spread for a slightly wider lid opening. The square‑wire form adds blade rigidity for cases where firmer lid retraction is needed. A dull finish minimizes reflections during microscope work.
The Guyton‑Park speculum carries solid 14mm blades with a 45mm spread, dull finish, suture posts, and a canthus bar, sized for stable wide exposure during oculoplastic and complex anterior segment cases. The integrated suture posts allow lid‑traction sutures to be anchored at the speculum, and the canthus bar protects the lateral canthus during sustained retraction.
The Jackson lacrimal intubation set pairs two 20 gauge thin‑wall malleable probes, each 155mm long, with 300mm of silicone tubing fastened to the probe ends. The surgeon shapes each probe to match the canalicular path, then draws the silicone stent through the nasolacrimal system to maintain patency. Blunt probe tips protect canalicular mucosa during passage.
The Nagahara nucleus spatula is engineered for safe lens-nucleus mobilization during phacoemulsification and manual small-incision cataract surgery. The angled geometry with 11mm bend-to-tip creates optimal mechanical advantage for nuclear rotation and wedging. Flat-edge design prevents capsule trauma, while stainless steel construction enables lasting performance.
The Westcott stitch scissors provide sharp, pointed blades for suture removal and fine stitch cutting during anterior segment revision. The serrated flat handle ensures secure grip without rolling, while the polished finish enhances visibility. The 108mm straight geometry supports precise positioning during delicate suture work.
This Drysdale nucleus manipulator and capsule polisher features a flattened paddle tip with a large teardrop‑shaped surface for broad nucleus support and polishing. The round knurled handle provides stable control during intraocular lens manipulation and cortical clean‑up.
This Bores O‑Z marker bridges mid-range anatomical marking with its 4.75mm circular imprint. The precisely sized contact area identifies pupillary borders and arcus zones during anterior segment assessment. The smooth handle and 100mm shaft deliver repeatable positioning and pressure control.
The Youens LASIK lens manipulating cannula is designed for safe flap positioning and IOL manipulation during refractive and cataract surgery. Its 30-gauge double-angled geometry allows ergonomic access under the LASIK flap and around the optic. The 0.8mm port and 17mm working length support controlled fluid delivery and lens positioning in confined anterior chamber spaces.