Your cart is empty!
The Nichamin titanium quick chopper features a left‑hand dominant double‑ended design with wedge‑shaped cutting edge on one end and delicate needle‑point pick on the other, accommodating both nuclear sculpting and fine tissue manipulation. Titanium rigidity and dual functionality reduce instrument exchanges during time‑sensitive phaco sequences. The pick end enables precise posterior capsule work.
Features & Benefits
Nichamin LASIK cannulas deliver a flat vaulted tip on a 27‑gauge shaft for irrigating the LASIK interface after flap creation without scoring the stromal bed. The vault profile lifts the flap edge as the cannula sweeps, allowing thorough debris removal under controlled flow.
A 25ga curved shaft with a uniquely flattened tip lets the Nichamin long hydrodissection cannula direct a smooth fluid wave beneath the anterior capsule during cataract work. The 35mm usable length reaches across the equator for thorough cortical‑capsular separation while keeping focal jetting low.
Nichamin long hydrodissection cannula extends reach for posterior hydrodissection and lens nucleus manipulation in deeper cataracts. The curved geometry and 27ga fine gauge permit safe navigation through small incisions, while the unique flattened tip controls fluid distribution. At 47.6mm overall length, this cannula supports access to posterior cortical and epinuclear zones.
Nichamin LRI (limbal relaxing incision) knife in black‑gold titanium combines a micro 20‑degree profile with a flip‑tip design for precise limbal astigmatism correction. The seven‑step handle offers preset depths at 0.45, 0.50, 0.55, 0.60, 0.70, and 0.75mm, enabling reproducible incision depths across cases. The 0.8 × 0.1mm blade dimensions deliver tissue‑plane precision for modern MICS and refractive work.
This Nichamin quick chopper carries a 1mm eye-shaped wedge with a right-hand-dominant cutting edge, intended for use in the surgeon's left hand during stop-and-chop technique. The angled shaft sets the tip 10mm from the bend, supporting clean nucleus segmentation through a paracentesis. Overall length is 114mm.
The Nichamin quick chopper's eye-shaped wedged cutting edge presents a unique profile for selective nucleus cracking without the flanged tips that catch surrounding tissue. Left-hand dominant design allows right-hand use while positioning the cutting edge at an ergonomic approach angle. Its 10mm angled tip from bend improves field control during grade 2-4 nucleus work.
This combination instrument pairs the Nichamin triple chopper with a quick-chopper end, engineered for left-hand-dominant surgeons working right-handed. Both ends feature the characteristic Nichamin multi-directional cutting geometry optimized for efficient nucleus fragmentation in varying density cataracts. Round knurled handle and stainless steel construction support high-demand phaco workflows with a single dual-purpose instrument.
Optimized for right-hand-dominant surgeons requiring left-hand use, this double-ended instrument combines a Nichamin triple chopper and quick-chop end with ambidextrous geometry. The round knurled handle and stainless steel construction deliver comfortable grip and reliable reprocessing durability. Multi-directional cutting edges address nucleus density variation within a single instrument, reducing hand exchanges during phaco.
The Nichamin Triple Chop and Quick Chop combination delivers dual chopping techniques within a single titanium instrument, allowing surgeons to transition between heavy fragmentation and fine finishing without instrument exchange. Right‑hand dominant design with round knurled handle supports sustained, fatigue‑resistant grip during multiple chopping sequences in grades 2‑4 nuclei.
The Nichamin triple chopper Castroviejo spatula combines precision nuclear disruption with convenient tying platform geometry in a single instrument. Its 0.5mm Castroviejo‑pattern tip allows fine, controlled chopping strokes during phaco, while the straight shaft and round knurled handle support stable handheld control. The 140mm overall length facilitates comfortable manipulation during lens nucleus management.
The Nichamin triple chopper combines three distinct cutting edges optimized for multi-directional nucleus division in a single ambidextrous instrument. The angled 10mm bend-to-tip, sharp multi-directional wedge, and round knurled handle deliver superior control during aggressive nucleus cracking in hard cataracts. Stainless steel construction supports high-demand phaco surgery centers with reusable efficiency.
Nichamin's triple chopper delivers multi-directional cutting action for dense nucleus management. The titanium construction balances rigidity with field control, while the 10mm angled segment from bend to tip improves tactile feedback during sequential chopping passes. Knurled round handle and ambidextrous design support comfortable use in either hand.
This double-ended titanium instrument combines the Nichamin Triple Quick Chop and Bechert Rotator in one surgical tool. The right-hand dominant configuration and vaulted profile support both nucleus chopping and controlled segmentation during phacoemulsification. Single-instrument design reduces exchanges and maintains field efficiency during complex cataract cases.
Engineered as an ambidextrous vertical chopper, the Nichamin chops the nucleus by downward force rather than lateral pull. The angled, vaulted shaft places the tip 10mm from the bend, clearing the iris plane during vertical chop maneuvers. A 114mm overall length keeps the instrument balanced for in-the-bag work.
The Nightingale capsule curette carries a 1.75mm semi‑sharp ring at the end of a shaft angled with 10mm from tip to bend, sized for residual cortical and capsular polishing after lens extraction. The round knurled handle delivers smooth rotational control as the ring sweeps the capsular bag.
Ring?tip geometry distinguishes the Nordan capsule elevator, distributing load across the lens capsule surface to reduce perforation risk during nuclear management. Its angled configuration supports subsurface elevation of nucleus or posterior capsule during phacoemulsification. The round handle supports secure yet sensitive control.
Nordan Colibri forceps feature ultra‑precision 0.12mm angled tips with 1×2 teeth and integrated alignment pin for exacting corneal suture placement. The flattened round knurled handle balances control with minimal hand pressure, optimal for extended microsurgical cases.
Nordan special Colibri forceps carry 0.12mm 1 × 2 teeth in the Colibri offset pattern for fixation at the corneal wound edge without obstructing the surgeon's view through the microscope. A round knurled handle without side flats preserves continuous rotational grip, and an alignment pin keeps the tip teeth in register during closure. The 104mm overall length suits cataract and corneal wound suturing.
The Nordan-style Colibri forceps delivers micro-precision grasping for delicate capsulorhexis and lens manipulation with its 0.12mm tapered tips and 6mm tying platforms. Titanium construction provides lightweight handling without sacrificing rigidity, while the round flat grip and 115mm length support sustained control during extended anterior chamber work.
This nucleus hydrodissection cannula is a 27ga device angled 35� with an 8mm bend‑to‑tip distance and a horizontally flattened curved tip. The configuration supports targeted hydrodissection beneath the nucleus for rotational mobilization.
This curved nucleus hydrodissector provides controlled hydropressure for nucleus groove creation and final cortical mobilization. The 27 gauge standard curve geometry adapts to chamber angles while the blunt design prevents endothelial trauma. Sterile single‑use format guarantees consistent performance and blade edge definition across every surgical case.
The Nugent utility forceps features 10mm crisscross serrated jaws in 45‑degree angled configuration suited to tissue grasping and dressing manipulation in varied surgical fields. The broad jaw width distributes holding force across substantial tissue surface, while the angled shaft provides ergonomic access. Durable construction supports routine reprocessing.
These Nugent utility forceps carry 10mm smooth jaws on shafts angled 45 degrees, lifting and positioning tissue or sutures without point pressure. The angled shaft profile clears the surgeon's line of sight to the cornea, and the 110mm overall length keeps fingertip control at the orbital rim.
This stainless steel Nuijts‑Solomon toric IOL axis marker has a 50mm optical zone and lateral blades designed for use with a beveled Mendez degree gauge. The design facilitates toric IOL axis transfer from pre‑operative reference marks.
The O'Brien fixation forceps combines straight shafts with 1 × 2 Elschnig‑style tooth pattern suited to capsule and tissue fixation across varied cataract approaches. The precise tooth geometry prevents slippage and crushing, and the straight configuration enables stable control during bimanual surgery. Durable construction supports routine sterilization cycles.
O'Connor scleral depressor-marker serves dual functions during ophthalmic examination and surgery. The 3mm teardrop‑shaped depressor end provides broad scleral contact for gentle indentation and localization, while the 1.5mm Gass marker end enables precise marking of surgical landmarks. Serrated flat handle and polished finish support secure grip and clean intraoperative handling.
The O'Connor‑Elschnig fixation forceps combine heavy Elschnig teeth with a slide‑style lock to stabilize the globe during strabismus and extraocular work. Straight shafts give a direct line of approach, and the serrated flat handle delivers controlled purchase across repeated fixation maneuvers.
The O'Gawa Castroviejo tying forceps features a 6mm tying platform with straight shafts optimized for fine monofilament and nylon passage during anterior segment closure. The broad platform distributes knot‑tying force across stable contact, while the refined Castroviejo geometry ensures consistent suture manipulation. Fine tip configuration minimizes mucosal trauma.
O'Gawa Colibri forceps deliver ultra‑fine 0.12mm angled tips with 1×2 Colibri‑pattern teeth for precision corneal edge stabilization. The alignment pin integrates rotational reference, supporting microsurgical suturing in confined anterior chamber spaces at 106mm length.