Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
This Henderson pre‑operative reference marker uses a durable half‑circle geometry with blunt positioning pins at 0�, 90�, and 180�. The round knurled handle improves grip security during toric axis pre‑marking while minimizing rotational drift.
Features & Benefits
Used in endoscopic brow lift, this Daniel-style forehead elevator releases the periosteum across the supraorbital rim and lateral forehead. A slightly curved shaft delivers the 6 × 25mm blade into the subperiosteal pocket along the frontal bone contour, and a 5-3/8 inch (135mm) working length within a 9-1/2 inch (242mm) overall body reaches the orbital rim through small endoscopic ports. Stainless‑steel construction preserves the blade edge across repeat reprocessing.
Designed for left‑hand use during right‑dominant phacoemulsification, this Nagahara phaco chopper carries a flat interior cutting edge that initiates clean nuclear fracture along the chopping axis. The shaft is angled 45 degrees with a 10mm bend‑to‑tip and a 1.5mm cutting edge oriented at 60 degrees, giving the surgeon a defined purchase point on the nucleus while clearing the capsular rim. A round knurled handle on the 114mm shaft keeps rotational control predictable through divide‑and‑conquer or stop‑and‑chop technique.
Gruenwald nasal dressing forceps deliver precise tissue manipulation within the nasal vestibule and intranasal cavities during rhinoplasty and sinus surgery. The 2mm tip width suits confined sinonasal anatomy, while the 105mm working length maintains adequate visualization of deep nasal passages. Balanced spring tension supports secure cottonoid placement and removal across reusable clinical cycles.
Curved fine jaws define this Halstead mosquito forceps for delicate hemostasis on small vessels and bleeders. Serrated 25mm jaws hold cleanly without crushing surrounding tissue, and the standard curve lets the tip slip around vessels during ligation. The 140mm length keeps the instrument compact in superficial fields.
Senn retractor combines three blunt prongs with a smaller central plate for efficient tissue spreading in confined surgical fields. The multi‑element design distributes retraction across distinct planes, reducing localized compression. Blunt tines minimize tissue trauma during sustained retraction.
This insulated right‑angled hook scissors provides controlled cutting during plastic surgery flap elevation and fascial dissection. The 30‑degree rightward curve geometry suits left‑handed and right‑handed approaches to facial and cervical tissue planes. A 3.4mm shaft and 127mm working length deliver precision during extended rhytidectomy or body lift procedures.
These titanium McPherson tying forceps are angled and include 5mm tying platforms for secure knot support. The three‑hole handle and 105mm overall length enhance rotational and axial control.
The Daniel‑style forehead nerve hook carries a 9mm small right‑angled hook on a half‑curved 130mm working shaft, sized for protecting and lifting the supraorbital and supratrochlear neurovascular bundles during endoscopic brow lift. The 235mm overall length keeps the handle out of the small endoscopic incision.
This Barraquer microsurgical needle holder is curved with delicate 8mm jaws and no locking mechanism for high‑precision suturing. The 133mm length and fine profile support controlled manipulation of micro‑sutures.
Designed for iris tissue handling during anterior segment surgery, these straight Graefe iris forceps feature fine serrated tips that grasp the iris margin without crushing. The 70mm compact length supports tactile control through limbal or paracentesis access. Polished stainless steel construction holds up to repeat sterilization cycles.
This dura hook measuring 8" gently retracts delicate neural and vascular structures. Blunt tip design prevents inadvertent tissue trauma during dissection. Stainless‑steel construction provides reliable performance across many surgical cases.
This 203mm curved Metzenbaum scissor extends reach into deep surgical fields while maintaining the signature blunt-tip safety profile. The curved blade geometry aligns with natural approach angles in abdominal and thoracic exposures. Excellent for prolonged dissection in extensive laparotomy procedures.
Used to outline the optical zone during refractive keratotomy and corneal procedures, the Bores O‑Z marker imprints a 6.5mm circular reference on the corneal epithelium. The smooth handle supports light, consistent contact pressure, and the 100mm overall length keeps the instrument well balanced over the eye. The straight shaft preserves a perpendicular approach to the corneal surface.
Angled iris scissors provide the curved cutting geometry essential for fine dissection along tissue contours and confined spaces. The 114mm compact length combined with ring-handle design ensures stable control during delicate work. Stainless-steel construction maintains edge quality across cases.
The small Jameson muscle hook engages extraocular muscle bellies during strabismus surgery. Its slim shaft and rounded tip slide beneath the muscle insertion to lift it clear of the sclera for measurement, recession, or resection. A grooved handle improves grip during the controlled lifting maneuver, and the 127mm length suits standard pediatric and adult strabismus exposure.
The Jacobson mosquito forceps delivers fine hemostatic control in delicate surgical fields requiring precise vessel occlusion. Its curved geometry facilitates access beneath surface structures while maintaining reliable jaw closure across minor vessels. The 127mm length and proven spring action support extended use without fatigue.
The Mayo-Hegar needle holder features tungsten-carbide jaws that maintain precise needle grip through hundreds of surgical cases without dulling. The straight 152mm design provides optimal control and visibility during general and vascular suturing. Carbide construction combines reliable edge retention with corrosion resistance over extended clinical use.
Widened to 51mm, this Ribbon retractor accommodates major organ retraction in extensive laparotomy while the malleable construction allows field-specific shaping that protects underlying viscera. Stainless steel supports repeated sterilization and reshape cycles. The 330mm overall span reaches deep abdominal planes.
The curved iris forceps features delicate lightly curved tips with 1 × 2 mouse‑style tooth pattern optimized for gentle iris manipulation without trauma. The curved shaft geometry suits approach to the iris plane during anterior segment work. The fine tips and delicate construction minimize bleeding and tissue damage.
Cooley first rib shears are heavy‑duty cutting instruments for median sternotomy and thoracic surgery approaches to coronary bypass and heart transplantation. The curved jaws with 340mm length provide mechanical advantage for cutting through dense rib and sternal bone during cardiac access. Stainless steel construction withstands repeated autoclave sterilization and maintains blade sharpness across multiple cases.
This obtuse pick (0.25mm tip, 30-degree angle) enables ultraprecise dissection in confined ossicular spaces. Its minimal tip diameter (0.25mm) allows work in microscopic tympanic anatomy. The 30-degree angle supports access to posterior epitympanic niches and sinus tympani regions.
The Skinner 1 × 2‑tooth forceps with delicate pattern provides light interlocking grip suited for sensitive tissue handling in general surgical procedures. The 229mm extended length enables deeper field access while maintaining fine‑tip control. The straight geometry preserves operative field visibility.
Smith‑Peterson laminectomy rongeurs are engineered for precise laminar and foramen bone removal with a 3mm × 16mm bite footprint that balances precision with cutting efficiency. The spring handle absorbs impact and reduces hand fatigue during multiple strokes through dense vertebral structures, and the standard curve positions the jaw perpendicular to the spinal midline. The 241mm length provides stable control during deep cervical and lumbar access. Stainless steel maintains durability.
The titanium Castroviejo tying forceps in straight configuration features 7mm tying platform and refined geometry suited to clear visualization during IOL and corneal knot placement. The straight shafts enable unobstructed view of knot formation, and titanium construction offers enhanced durability. The broad platform ensures consistent tying force distribution.
These 8‑inch DeBakey needle forceps pair a 2mm tungsten carbide tip with the characteristic atraumatic Russian‑pattern jaws for precise needle manipulation in deeper surgical fields. The 203mm shaft length gives comfortable reach during vascular and intra‑abdominal closures, while tungsten carbide jaw inserts hold needle grip across many cases without rounding.
The titanium Sheets‑McPherson tying forceps in 45‑degree angled configuration combines 10.5mm tying platform with reduced weight compared to stainless steel. The angled geometry provides ergonomic access during bimanual IOL and corneal surgery. Titanium construction offers corrosion resistance and enhanced durability over many sterilization cycles.
This modified Barraquer speculum opens the lids with 15mm solid blades shaped longer and 8mm deep for procedures needing extended palpebral exposure. The 26mm outside by 10mm inside spread holds the lids clear of the cornea while preserving working access through the aperture. A dull finish across the 43mm body reduces microscope glare during anterior segment cases.
Lambotte osteotome, 25mm wide and curved, delivers controlled cutting force for bone osteotomy, fusion site preparation, and fracture reduction. The 230mm length provides mechanical advantage and hand control during hard bone work. Stainless steel ensures durable edge retention and reliability for repeated surgical use.
This nine-prong Miller wound retractor delivers broad superficial tissue retraction through blunt prong geometry optimized for skin and superficial soft tissue exposure. The multi-prong design distributes tension evenly across the wound edge, reducing tissue trauma during extended procedures. Handheld design enables dynamic retraction when needed.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.