Your cart is empty!
This Barnhill adenoid curette, size 0, uses a 13×14mm curved head with a 10mm cutting edge and a Bruns‑style handle with a 222mm overall length for controlled adenoid removal.
Features & Benefits
This Barnhill adenoid curette, size 1, incorporates a 15×16mm curved head with a 12mm cutting edge and a Bruns‑style handle across a 222mm length for efficient tissue curettage.
This Barnhill adenoid curette, size 2, features a 17×18mm curved head with a 15mm cutting edge and a Bruns‑style handle for controlled removal of larger adenoid tissue volumes.
Barnhill adenoid curettes Size 3 deliver controlled removal of hypertrophied adenoid tissue during routine tonsillectomy and adenoidectomy procedures in adolescent and adult patients. The 19 × 20mm curved head with 16mm cutting edge provides adequate working geometry for efficient tissue debulking. Bruns-style handle offers familiar ergonomic grip during controlled nasopharyngeal dissection.
The Barnhill adenoid curette size 4 removes adenoid hypertrophy and lymphoid tissue during pharyngeal surgery. Its 21 × 22mm curved head with 18mm cutting edge efficiently evacuates disease from the nasopharynx. The Bruns style handle and 222mm length support extended reach and control.
This Baron suction tube, 3Fr, features an angular design with a thumb plate cutoff bypass, a 90mm long working length, and a total length of 155mm to support controlled otologic suction.
The Baron 3 French suction tube angles the tip with a thumb‑plate cutoff bypass on a standard 75mm working length, sized for fine otologic and microsurgical fluid clearance. The thumb‑plate bypass supports continuous suction line connection with intermittent flow at the working face.
This Baron suction tube, 5Fr, incorporates an angular shaft with a thumb plate cutoff bypass, a 90mm long working length, and a total length of 155mm for increased suction capacity.
The Baron 5 French suction tube sits between the 3 French and 7 French variants for fine‑to‑moderate otologic and ENT flow. The angular shaft preserves visualization, and the thumb‑plate cutoff bypass supports continuous suction line connection.
This Baron suction tube, 7Fr, features an angular configuration with a thumb plate cutoff bypass, a 90mm long working length, and a 155mm overall length for robust otologic suction.
Stepping up to 7 French, this Baron suction tube delivers moderate flow for otologic and ENT work where the 3 French and 5 French variants are too fine. The thumb‑plate cutoff bypass supports continuous suction line connection with intermittent flow.
This 7Fr Baron suction tube delivers controlled fluid evacuation across ENT and general surgical fields where a slim straight cannula is preferred. The 94mm working length within an overall 146mm shaft balances reach with surgeon control at the field. Stainless‑steel construction holds up across repeat sterilization cycles in routine clinical use.
This Baron suction tube delivers controlled fluid and debris removal through an angled tip configuration optimized for general and specialty surgical fields. The 5Fr bore and 102mm working length balance suction capacity with tactile control, allowing surgeon-modulated aspiration without tissue trauma. Reinforced construction supports hundreds of reprocessing cycles without degradation.
The angled Becker septum scissors combine squeeze handle design with serrated blades for controlled septal mucosa and cartilage cutting in septorhinoplasty procedures. The angled geometry improves visualization along septal contours, and the serration secures tissue without slippage. The 161mm length provides balanced reach for nasal work.
This Beckman adenoid curette (Size 5, 14.5mm) delivers focused tissue removal during pediatric adenoidectomy. The 200mm overall length provides mechanical advantage while the 14.5mm cup diameter accommodates the adenoid bed dimensions. The straight design prevents inadvertent contact with the soft palate.
The Beckman adenoid curette (Size 6, 17.5mm) offers a larger cup for adenoid removal in older children and young adolescents. The 200mm length provides ergonomic control while the 17.5mm diameter cup accommodates larger adenoid tissue volumes. The straight geometry prevents palatal contact during intraoperative manipulation.
Angled 90 degrees at the working end, this Bellucci pick brings a 0.5mm tip into precise contact with ossicular structures during stapedectomy and middle‑ear reconstruction. The right‑angle geometry reaches behind the incus and stapes superstructure where straight instruments cannot follow. Stainless steel construction maintains tip integrity through repeat ototology cases and reprocessing cycles.
These Bellucci ear scissors feature a left-curved blade geometry scaled for fine tympanic and aural dissection. The large model sizing accommodates surgeon hand comfort while the curved profile facilitates work around mastoid and ossicular structures.
These curved right Bellucci ear scissors provide controlled dissection in the mastoid cavity and middle ear spaces during otologic procedures. The large model geometry delivers substantial cutting power while maintaining fine tip precision for delicate ossicular and mucosal work. The right curve supports access to left‑sided mastoid structures.
The Bellucci large‑model scissors with 8mm blades and straight configuration deliver robust cutting capability for large tissue planes and cartilage dissection in otologic and lateral neck procedures. The large blade width reduces the number of passes needed for thick tissue. Reusable stainless‑steel maintains its cutting edge.
The Bellucci large‑model ear scissors with 8mm blades and 100mm working shaft deliver controlled cutting in the limited ear canal and mastoid spaces during otologic procedures. The extended working shaft maintains visualization while the large blade width accommodates thicker cartilage. Stainless‑steel construction ensures lasting clinical durability.
The Billeau ear loop provides a 3mm medium diameter working end and 6.5 inch overall length for flexible cerumen removal and aural debris retrieval. The figure 2 design allows the operator to modulate loop depth and angle during cerumen extraction while the round knurled handle distributes grip force evenly across the palm. Reusable stainless steel withstands repeated processing and autoclave cycles.
The Billeau large ear loop with 4mm × 7mm oval configuration and flexible shaft provides atraumatic removal of larger cerumen impactions and foreign bodies from the ear canal. The flexible shaft navigates canal anatomy without applying pressure to the canal wall. The round handle enables controlled rotation and extraction.
This large Billeau ear loop measures 4mm and extends 152mm to support atraumatic retrieval and positioning of ossicles during mastoid and middle ear surgery. The straight loop geometry prevents tissue pinching, while the generous length facilitates handling in confined aural spaces.
Sized with a large 4mm working loop, this Billeau ear loop removes cerumen and small debris from the external auditory canal. The 165mm length keeps the operator's hand clear of the otoscope's field of view, and the sharpened loop edge passes cleanly under impacted wax without driving it deeper.
The Billeau medium ear loop features a 3mm wire loop designed for atraumatic removal of cerumen impactions and foreign bodies from the ear canal. The smooth loop material prevents mucosal abrasion. The 152mm straight shaft provides tactile control and direct visualization during cerumen curettage.
The medium Billeau ear loop carries a 3 × 5mm working loop on a flexible shaft with a round handle, sized for routine adult cerumen removal where the loop must follow canal curvature. The 161mm length keeps the operator's hand clear of the otoscope's field.
The Billeau ear loop is a specialized aural retractor used to expose the lateral canal wall and auricular anatomy during otologic procedures. Its 3mm medium-size loop diameter creates gentle tissue contact while providing adequate visualization of the ear canal and posterior auricular field. The straight 165mm handle allows precise positioning without obstruction.
The Billeau ear loop size 2 with smooth square handle delivers classic design for cerumen and foreign body removal from the auditory canal. The smooth handle minimizes tissue trauma during manipulation. 159mm length provides adequate hand leverage during canal work.
The Billeau ear loop is a precision instrument for mobilization and retrieval of ossicles and small fragments during middle-ear surgery and ossicular reconstruction. Its 2mm loop maintains gentle traction without tissue crush. Stainless-steel construction resists corrosion in the middle-ear cavity.