Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
This angled Sinskey hook carries a 0.2mm tip for engaging IOL positioning holes during lens manipulation and capsular bag fixation. The round knurled handle supports fingertip rotation through the hook's working arc, and the 115mm body keeps fingertips clear of the cornea during phaco and IOL implantation.
Features & Benefits
The straight Sinskey hook carries a blunt 0.2mm tip on an 18mm shaft for IOL dialing, nuclear rotation, and capsular bag exploration. The round knurled handle delivers steady fingertip rotation, and a protective guard sheaths the delicate tip between uses to prevent damage during storage and transport.
This reversed Sinskey iris/IOL hook uses a 0.2mm reverse‑curved tip designed to engage haptics or iris tissue atraumatically. The 12mm bend‑to‑tip geometry improves approach angles within the capsular bag, while the polished round handle provides smooth rotational feel during micro‑adjustments.
Sinskey II hooks are a workhorse for IOL positioning and rotation. This straight model carries a 0.2mm tip on a 22mm shaft, giving the surgeon fine engagement of haptics and capsulorhexis edges through small incisions. The flat handle keeps the working axis predictable during dial maneuvers, and the 120mm overall length suits standard anterior segment reach.
Designed for iris retraction and IOL manipulation, this straight Sinskey hook carries a 0.2mm working point on a straight shaft. The serrated flat handle gives positive grip during dialing maneuvers and resists rolling on the drape, while the 121mm overall length suits standard anterior segment access. The straight profile keeps the tip in line with the shaft for predictable purchase.
Angled at the tip, this Sinskey hook features a fine 0.25mm working point for IOL positioning and iris manipulation during cataract surgery. The round knurled handle gives controlled rotation as the surgeon engages haptics or dials the lens into the capsular bag. At 110mm, the shaft suits standard anterior segment access.
The Sinskey hook is a fine iris manipulation instrument featuring a 0.18mm angled tip ideal for anterior capsule retraction and zonule management during cataract surgery. Its angled shaft with 10mm bend to tip positions the hook optimally for indirect iris and capsule engagement. Titanium construction ensures durability while the round handle provides stable palmar control.
The Sinskey Hook is a foundational ophthalmic manipulator designed for fine anterior segment and capsular work. Its 0.25mm straight tip provides delicate capsular engagement during capsulorhexis, IOL positioning, or iris repositioning. The flat handle offers precise finger control in confined surgical spaces, and the 121mm length balances maneuverability with adequate working distance in the anterior chamber.
A fine 0.25mm working tip makes this Sinskey hook well suited to IOL dialing and iris manipulation through small incisions. The straight shaft preserves a direct approach, and the round knurled handle gives the rolling tactile feedback surgeons rely on during lens rotation. The 110mm overall length keeps the working hand clear of the orbital rim.
This reversed Sinskey iris IOL hook brings a 0.2mm reverse hook tip to DSAEK procedures where fine IOL positioning and iris manipulation demand micron-level control. The 12mm bend-to-tip geometry supports reach beneath the iris, while the polished round handle enables tactile rotation and withdrawal of the lens.
This angled Sinskey iris and IOL hook delivers a blunt 0.2mm hook for delicate iris and lens implant manipulation. The angled geometry optimizes access to posterior capsule, IOL haptics, and pupillary borders during phacoemulsification and IOL placement. The serrated flat handle provides secure tactile control throughout complex anterior segment procedures.
This custom Sinskey hook features a 0.2mm elongated tip and an 11mm angled shaft for extended reach under the anterior capsule. The round knurled handle provides enhanced micro‑traction for delicate rotational adjustments during IOL positioning.
This reversed Sinskey hook variant maintains the same 0.2mm reverse tip and 12mm bend‑to‑tip distance but incorporates a polished round handle optimized for consistent glide and low‑resistance manipulation during IOL positioning.
Intracapsular and cortical manipulation demands ultimate precision, which the Sinskey hook delivers via its 0.2mm fine tip and 18mm straight shaft. The included guard protects the delicate tip during handling and sterilization. Its 114mm round knurled handle provides reliable tactile feedback during fine anterior chamber work.
This guarded Sinskey hook features an 18mm straight shaft and a 0.85mm blunt tip engineered for safe capsule engagement. The knurled round handle and integrated guard enhance grip and prevent excessive tip advancement in confined anterior chamber spaces.
This modified Sinskey hook carries a fine 0.2mm tip on a curved shaft, giving the surgeon a shorter working radius for IOL repositioning and capsular bag rotation. The serrated flat handle provides tactile rolling feedback during dialing maneuvers, and the polished finish maintains a clean appearance under microscope illumination. The 120mm overall length offers comfortable balance during anterior segment work.
This titanium Sinskey iris IOL hook is engineered with a straight shaft and 0.2mm fine tip for precise hook-based IOL dialing and iris reposition during cataract implantation and secondary IOL work. The flat handle and smooth titanium finish enable atraumatic haptic and optic engagement. A 119mm length balances reach with tactile control.