This grooved director combines a longitudinal channel for safe scalpel guidance with a tongue‑tie terminal for ligature retrieval and probe duty. The 152mm straight shaft supports duct dissection and superficial tract exploration. Stainless‑steel construction holds calibration across repeat sterilization cycles.
Features & Benefits
The 140mm tongue‑tie grooved director carries a flat shaft with a longitudinal groove and a forked tongue‑tie end, sized for separating tissue planes during oral and general surgical dissection. The grooved center guides a blade or scissors along the line of dissection.
Sized at 152mm, this longer tongue‑tie grooved director adds reach beyond the 140mm format for general surgical dissection where the surgeon needs more working length. The forked tongue‑tie end and grooved center suit the same plane‑guidance role.
This handheld demagnetizing probe removes residual magnetism from surgical instruments post-sterilization, preserving instrument integrity and preventing artifact during magnetic-sensitive procedures. The stainless steel construction withstands routine handling and cleaning. Reusable design supports ongoing clinical use across multiple sterilization cycles.
This hemorrhoid suction ligator features a cone‑shaped tip geometry that seats securely within hemorrhoidal tissue during suction ligation procedures. The funnel design directs hemorrhoid tissue into the ligation chamber while maintaining controlled suction engagement. Reusable stainless‑steel construction ensures reliable performance across multiple cases.
This hemorrhoid ligator delivers controlled tissue ligation for hemorrhoid ablation. Precise geometry ensures reliable, repeatable application without tissue slippage. Stainless‑steel construction supports reliable performance across many cases.
This J‑shaped electrode is designed for monopolar electrosurgery with insulation protecting the operator throughout the shaft. The J‑geometry provides approach flexibility in confined operative spaces. At 451mm extended length, this instrument reaches deep surgical cavities while maintaining safe current delivery.
This Jacobs chuck is engineered for reliable coupling and secure grip of rotary instruments (drills, burrs, reamers) during orthopedic bone work. The self‑centering chuck jaws provide repeatable holding accuracy without marring instrument shanks, essential for precise alignment during intramedullary reaming or cortical drilling.
Keyes dermal punches create full-thickness skin biopsies in dermatological and general surgical settings. The 1.5mm circular aperture produces uniform sample cores suitable for histologic examination. Straight geometry and compact length support precise positioning on facial and body surfaces.
The Keyes dermal punch at 2mm cuts a circular skin biopsy or excision in dermatologic and minor surgical settings. The sharpened circular blade delivers a clean full‑thickness skin sample in a single rotational stroke, and the 102mm body keeps the operator's hand clear of the working tip.
The 3mm Keyes dermal punch cuts a circular skin biopsy or excision at the smallest standard diameter, suited to fine lesion biopsy in dermatology where minimal margin is needed. The sharpened circular blade delivers a clean single‑stroke sample.
A 4mm Keyes dermal punch cuts circular skin specimens for biopsy and minor excisional procedures. The cylindrical cutting edge produces clean, full‑thickness cores with minimal trauma to surrounding dermis. At 100mm overall, the handle gives a stable grip for controlled rotation through the skin.
Keyes dermal punch with 4mm bite creates uniform circular tissue specimens for skin and soft-tissue biopsies. The straight 102mm length supports hand control during punch placement. The circular cutting edge produces clean, consistent tissue cores suitable for histological examination.
The 5mm Keyes dermal punch cuts a circular skin biopsy or excision in dermatologic settings where a wider‑diameter sample is needed than the smaller punches provide. The sharpened circular blade delivers a clean full‑thickness specimen in a single rotational stroke, and the 100mm body keeps the operator's hand clear of the working tip.
Sized at 6mm, the Keyes dermal punch bridges the 5mm and 8mm formats, suited to excisional biopsy and minor lesion removal where the 5mm punch is too small but 8mm exceeds the lesion margin. The sharpened circular blade cuts cleanly in a single stroke.
Sized at 8mm, the Keyes dermal punch cuts the widest standard skin sample in the Keyes family, suited to excisional biopsy of larger lesions where the diameter exceeds the 5mm and 6mm formats. The sharpened circular blade preserves a clean margin in a single stroke.
The Keyes dermal punch delivers a full-thickness circular excision of skin and dermis in biopsy and lesion-removal procedures. The 9mm diameter opening creates a uniform circular wound margin ideal for histopathology without need for secondary trimming. The 100mm straight shaft supports stable, perpendicular punch delivery with minimal twisting.
This lead hand protection for adults features side-mounted tabs on each fingertip, securing the lead apron to the hand during fluoroscopic procedures while maintaining proper positioning for repeated intraoperative X-ray imaging. The 356mm length accommodates adult hand span. Stainless steel tabs resist corrosion from sweat and sterilization.
Scaled for pediatric anatomy, this lead hand offers size-appropriate protection with side-mounted fingertip tabs that secure the lead apron during fluoroscopic examination or intraoperative imaging. The 241mm length aligns with child hand proportions while maintaining consistent positioning for repeated X-ray sequences. Stainless steel construction resists corrosion.
Titanium ligation aids guide sutures beneath blood vessels during vascular dissection and vessel isolation. The curved finger-like end contours to vessel topology, while the 0.4mm hole diameter precisely positions fine suture material. The shallow groove runs sutures without unintended vessel trauma, supporting controlled vascular ligation workflows.
This male Luer slip coupler in white nylon connects fluid lines via a slip‑fit male interface at the back table, sold individually for case‑by‑case stocking. The white nylon body resists chemical attack from prep solutions and irrigation fluids.
This male-to-male Luer slip coupler is fabricated from Kynar PVDF, providing chemical inertness and compatibility with a wide range of irrigation solutions and medications. The luer slip design enables rapid disconnection and reconnection without tool use. Supplied individually for flexible integration into custom sterile field setups.
McGivney hemorrhoidal ligators with offset handle geometry and large loading cone design enable single-handed placement of elastic O-rings over hemorrhoidal tissue. The 178mm working length provides reach into the anorectum during proctologic procedures. Offset handle positions the surgeon's hand clear of the optical path during anoscopic visualization.
These McGivney hemorrhoid ligator o‑rings are disposable elastomer bands that deliver elastic compression to hemorrhoid tissue, inducing ischemic necrosis and sloughing. Pack of 100 rings supports high‑volume banding procedures. Consistent elastomer composition ensures reliable, predictable band tension across applications.
This single‑ended Penfield #4 dissector delivers a lightweight, slightly curved working end for atraumatic tissue plane separation. The gentle curvature aids dissection along fascial boundaries without excessive tissue handling. Its 203mm length provides extended reach for deeper surgical exposures.
This Penfield Size 4 dissector delivers precise tissue-plane separation through a gently curved, lightweight design optimized for careful dissection. The single-ended geometry and 203mm length provide reach and control during soft-tissue plane identification. Gentle curve minimizes trauma to adjacent structures during extended dissection sequences.
This replacement blade at 20mm diameter fits the standard finger ring cutter, restoring the cutting edge after wear. The blade is sized to seat in the ring cutter's drive collar, and the sharpened circular edge cuts through ring metal without overheating the surrounding finger tissue.
The #0 root elevator delivers controlled leverage for careful luxation and elevation of teeth during dental extraction and endodontic procedures. Its straight, narrow blade design distributes force along the periodontal ligament, minimizing damage to alveolar bone and surrounding gingival tissue. Engineered for fine intraoperative control, this 150mm instrument is essential for atraumatic root canal access and primary tooth extraction.
The #1 root elevator offers optimal blade geometry for leverage and luxation in routine dental extractions and endodontic access procedures. Its slightly broader profile compared to the #0 variant provides enhanced mechanical advantage while maintaining delicate tactile control around the periodontal ligament and alveolar crest. This 150mm instrument balances power and precision for maxillary and mandibular applications.
The reverse #1 root elevator is angled and offset to approach impacted or angulated roots from alternative vectors, improving access in confined oral spaces and around adjacent teeth. Its specialized geometry reaches roots that standard elevators cannot access comfortably, making it invaluable during complex extractions and endodontic procedures. The 150mm length and reversed blade orientation provide ergonomic control while minimizing trauma to surrounding periodontal and osseous structures.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.