Your cart is empty!
Enhanced port flow and improved chamber floor access during nucleus and cortical cleanup are provided by a 90‑degree angled I/A tip with 0.5mm port. The sharp angle reaches difficult epithelial locations while the port accommodates increased aspiration volume. The 45mm length supports comprehensive chamber irrigation.
Features & Benefits
This 0.3mm irrigation‑aspiration tip features a curved geometry and stainless steel construction designed for controlled fluid management during cataract extraction and hydrodissection. The curved profile naturally positions the port toward the surgical field, and the 45mm working length (1‑3/4 inch) provides comfortable hand positioning. Stainless steel maintains edge definition and corrosion resistance across multiple procedures.
This curved stainless‑steel I/A tip uses a gently curved geometry and 0.3mm aspiration port for oblique chamber access and cortex removal where straight tips can't reach. The 45mm length suits standard clear‑corneal entry, and stainless‑steel construction holds shape across repeated reprocessing.
Enhanced access to anterior chamber corners and peripheral epithelium during nucleus and cortical cleanup requires a curved I/A tip with 0.5mm port. The curved distal geometry reaches posterior epithelial deposits while the port maintains consistent aspiration flow. The 45mm length preserves adequate reach for all chamber quadrants.
Precise cortical cleanup and final chamber irrigation following nucleus extraction require a straight I/A (irrigation/aspiration) tip with fine 0.3mm port. The 45mm overall length provides adequate reach while the stainless‑steel bore maintains rigidity and consistent port geometry. The 0.3mm design minimizes turbulent flow during delicate epithelial aspiration.
This stainless‑steel straight I/A tip pairs a 0.3mm aspiration port with a 45mm overall length for controlled cortex removal and chamber irrigation during phacoemulsification. The straight profile suits standard clear‑corneal entry, and stainless‑steel construction holds shape across repeated reprocessing.
This stainless‑steel straight I/A tip is paired with a silicone sleeve for sealed irrigation and aspiration during phacoemulsification, with a 0.3mm port and 45mm overall length. The sleeve protects the wound during cortex removal while the straight shaft suits standard clear‑corneal entry. Stainless‑steel construction supports reliable performance across repeated reprocessing cycles.
Balanced irrigation volume and fine cortical control during nucleus and epithelial removal relies on a straight I/A tip with 0.5mm port design. The 45mm working length allows adequate reach for chamber corners while the port accommodates increased fluid flow. Stainless‑steel construction ensures consistent bore geometry and port reliability.
The 45‑degree angled titanium I/A tip with silicone sleeve delivers selective anterior chamber access for fragmented nucleus removal and cortical cleanup in micro‑incision workflows. The silicone jacket reduces trauma to lens material and the capsule, while the angled approach improves visibility and reduces excessive instrument manipulation. Titanium and silicone combination ensures durability and gentle handling.
This 45‑degree angled titanium I/A tip features a 0.3mm port configured for enhanced anterior chamber accessibility during dense cataract nucleus removal and selective hydrodissection. The angled geometry improves approach angle to the capsule and lens epithelium, while titanium construction ensures rigidity and corrosion resistance. The 45mm working length supports stable hand positioning.
This 45‑degree angled titanium I/A tip pairs a 0.3mm aspiration port with a 45mm shaft to reach the chamber angle and peripheral cortex during phacoemulsification. The angled geometry improves visualization and lets the surgeon clear cortex behind the iris without rotating the bottle. Titanium construction holds shape across repeated reprocessing.
This titanium angled I/A tip provides exceptional corrosion resistance and strength for repetitive anterior chamber instrumentation. Angled at 45 degrees, the 0.3mm port reaches oblique chamber angles and permits controlled cortical cleaving without excessive manipulation. Paired with silicone sleeve, the titanium construction is built for reliable performance and lasting durability across repeat clinical use.
Durable access to incision margin epithelium with consistent irrigation flow is provided by a titanium 45‑degree angled I/A tip with 0.5mm port. Titanium construction resists corrosion and maintains blade edge consistency across repeated sterilization. The angled geometry optimizes epithelial cleanup along the incision margin.
The 90‑degree angled titanium I/A tip brings a sharp approach angle for accessing the posterior lens surface and inferior capsular vault during dense nucleus manipulation. A 0.3mm port provides precise fluid control, and the right‑angle geometry minimizes collateral corneal and conjunctival contact. Titanium ensures lasting durability across high‑volume cataract workflows.
This 90‑degree titanium I/A tip combines a sharply angled shaft with a 0.3mm aspiration port to reach the subincisional cortex and the 12 o'clock capsular bag during phacoemulsification. The 45mm length and right‑angle geometry let the surgeon clear cortex behind the iris without rotating the bottle, and titanium construction holds shape across repeated reprocessing.
Durable access to chamber floor epithelium with sustained irrigation control is enabled by a titanium 90‑degree angled I/A tip with 0.5mm port. Titanium construction resists corrosion during multiple sterilization protocols while the angle reaches posterior epithelial locations. The port maintains consistent aspiration flow.
This curved titanium I/A tip combines a 0.3mm port with a standard curved profile ideal for gentle cataract extraction and cortical cleanup. Titanium construction delivers superior corrosion resistance and maintains edge definition across repeated processing, supporting long instrument life. The 45mm length (1‑3/4 inch) provides ergonomic control during hydrodissection and aspiration.
This curved titanium I/A tip pairs a 0.5mm port with a silicone sleeve for softer tissue aspiration and gentle nucleus handling during standard and micro‑incision cataract procedures. The larger 0.5mm opening reduces vacuum-induced trauma while maintaining efficiency, and the silicone jacket protects lens and capsular tissue. The 45mm length optimizes hand control.
Titanium durability is combined with enhanced access to anterior chamber peripheries and posterior epithelium in a curved I/A tip with 0.5mm port. Titanium construction resists corrosion during multiple sterilization cycles while the geometry reaches difficult epithelial sites. The port maintains controlled aspiration flow across all chamber zones.
This straight titanium I/A tip delivers a 0.3mm aspiration port across a 45mm shaft for controlled cortical cleanup and viscoelastic aspiration during cataract extraction. The straight profile suits standard clear‑corneal entry, and titanium construction resists corrosion while preserving fine port geometry across repeated reprocessing.
This straight titanium I/A tip combines a 0.3mm aspiration port with a 45mm overall length for controlled cortical cleanup and anterior chamber irrigation during phacoemulsification. The straight profile suits standard clear‑corneal entry, and titanium construction holds shape and port geometry across repeated reprocessing.
This straight titanium I/A tip is paired with a silicone sleeve for sealed irrigation and aspiration during phacoemulsification, with a 0.3mm port and 47mm overall length. The straight shaft suits standard clear‑corneal entry, while the silicone sleeve protects the wound during cortex removal and posterior capsule polishing. Titanium construction supports reliable performance across repeated reprocessing cycles.
Smooth, atraumatic anterior chamber contact during nucleus and epithelial cleanup is provided by a titanium straight I/A tip with integrated silicone sleeve. Titanium construction combined with silicone covering resists corrosion while reducing incisional trauma. The 0.5mm port and 45mm length enable comprehensive chamber access.
Enhanced durability across repeated sterilization cycles is combined with fine irrigation control in a titanium straight I/A tip with 0.5mm port. Titanium construction offers superior corrosion resistance while maintaining consistent bore geometry throughout many cases. The 45mm length provides adequate chamber reach.
Built for pairing with titanium I/A tips IAT‑01 through IAT‑13, this straight irrigating/aspirating handpiece manages cortex removal and capsular bag polishing after phacoemulsification. The 108mm titanium body delivers a rigid, lightweight feel that supports steady fingertip control through the paracentesis. Titanium construction resists corrosion across repeated autoclave cycles, keeping the handpiece reliable for high‑volume cataract use.
This irrigating-aspirating handpiece is a 110mm straight-shaft instrument designed to work with interchangeable stainless‑steel I/A tips for cortical cleanup following nucleus and lens fragment removal. The modular tip system (IAS-01 through IAS-13) supports a range of port sizes and geometries for efficient cortical material evacuation. Stainless‑steel construction ensures reliable reprocessing.
This irrigation/aspiration handle piece uses a male‑to‑male fitting to support connection between various I/A cannulas and tubing systems.
This straight one‑piece irrigation and aspiration handpiece features a 0.5mm port tip optimized for efficient removal of cortical and viscoelastic material during phacoemulsification. The integrated design eliminates connection points that might compromise flow or introduce debris. Overall length of 140mm maintains standard hand positioning and reach.
The McIntyre handpiece features a Luer‑connector aspirating/irrigating design with an 8mm diameter handle for efficient cortex removal and anterior chamber management. At 76mm compact length, its streamlined geometry preserves surgical visibility and intraoperative access. Stainless steel construction delivers reliable durability across extensive sterilization and reprocessing.
Replacement O-rings maintain the integrity of stainless-steel irrigation-aspiration (I/A) handpieces across multiple sterilization cycles. This five-set package provides diverse ring sizes for standard I/A tubing connections, ensuring airtight seals and reliable fluid control during cortical cleanup and anterior chamber irrigation.