Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
Measuring 10mm in diameter, this long trephine is supplied sterile in individual pouches for corneal transplantation and endothelial keratoplasty work. The extended length configuration provides controlled access to recipient corneas during DSAEK and DMEK button sizing. Single‑use sterile delivery ensures consistent blade sharpness and eliminates edge degradation from repeated reprocessing.
Features & Benefits
This long trephine cuts precise 11mm grafts for corneal transplantation and refractive keratoplasty procedures. The disposable format eliminates the variability of sharpness decline across multiple-use cycles, ensuring reproducible graft dimensions from case to case. Sold sterile in individual pouches for immediate deployment.
The reusable blue bipolar cord pairs an angled instrument end with two banana pins at the machine end, fitting bipolar forceps to compatible generators with mechanical retention at both interfaces. The angled instrument connection clears the operative line from the cord drape.
Angled 15 degrees on a 5.7mm blade, this microknife is built for slightly longer corneal entries than standard 5mm patterns. The added cutting length supports incisions sized for larger keratome paths, while the full handle preserves rotational control through the entry stroke. Sold individually sterile with six per box.
The 8.25mm long disposable trephine fills the gap between the 8mm and 8.5mm standard keratoplasty diameters, suited to surgeons who size grafts in 0.25mm increments. Single‑use sterile delivery removes reprocessing variability across cases.
This low‑turbulence phaco needle, angled 30 degrees, delivers controlled emulsification during cataract removal. The 20‑gauge stainless‑steel design with fine orifice geometry minimizes anterior chamber trauma. Sterile disposable format with integrated infusion sleeve supports consistent per‑case performance.
This 23‑gauge MVR blade is a single‑use sterile instrument designed for controlled pars plana puncture during micro‑incision vitreoretinal surgery. The straight profile delivers consistent blade sharpness case‑to‑case, eliminating the variability inherent in reusable instruments. Disposable sterility ensures no edge degradation across the procedure.
Angled at 60 degrees, this lamellar blade is configured for controlled stromal dissection during corneal lamellar work. The fixed bevel geometry supports a uniform plane through the lamellae, and the sterile presentation suits direct introduction to the operative field. Boxed in counts of six for rotation through scheduled cases.
The 12mm long trephine serves intermediate-sized corneal grafts in penetrating keratoplasty and refractive applications. Disposable construction guarantees sharp, predictable cutting performance on each use, while individual sterile packaging reduces operative field setup time. The straight cylindrical design ensures perpendicular graft geometry.
This 13mm long trephine serves the larger end of the graft spectrum in penetrating keratoplasty. Disposable design eliminates blade degradation across multiple cuts, ensuring consistent graft margin quality and epithelial alignment on each use. Pre-sterilized individual pouches support rapid surgical workflow.
At 5mm in diameter, this long trephine is packaged sterile for precision graft sizing in endothelial and posterior corneal work. The extended length provides the reach necessary for controlled positioning during DSAEK and DMEK recipient preparation. Single‑use design eliminates blade wear, supporting reproducible cutting geometry from case to case.
Sized at 7.75mm, this long disposable trephine sits between the most common keratoplasty graft sizes for surgeons who need that intermediate diameter. The single‑use stainless blade preserves first‑pass sharpness, and the extended handle stabilizes the cutting stroke.
Built with a double‑bevel cutting geometry, this 2.8mm angled phaco slit knife produces a self‑sealing main incision with reduced corneal distortion. The full handle gives steady control across the entry stroke, and the sterile single‑use format eliminates variability between cases.
These sterile disposable bipolar cords at 12 feet (3660mm) connect bipolar forceps to the electrosurgical generator across a full OR layout. The 10‑per‑pouch individually wrapped sterile format supports clean case‑by‑case setup without reprocessing overhead.
This 7.25mm disposable corneal trephine delivers a clean, full‑thickness donor or recipient cut for keratoplasty. The sharpened circular blade produces a true‑to‑size graft margin, and the long handle gives the surgeon stable control through the trephination stroke. Each unit is delivered sterile in a single pouch for case‑to‑case consistency.
Sized at 8.5mm, this long disposable trephine cuts donor buttons or recipient beds at one of the most commonly used keratoplasty diameters. The single‑use stainless blade arrives sterile in an individual pouch, removing reprocessing variability and protecting edge sharpness for a precise first‑pass cut.
This 9mm long trephine provides a precision cut for small corneal grafts and refractive tissue removal. As a disposable instrument, it maintains uniformly sharp cutting throughout the entire diameter, preventing the edge degradation and kerf widening that accumulate with reuse. Sterile pouch format enables efficient case setup.
Designed for phacoemulsification and micro‑incision cataract surgery, this 1.8mm angled slit knife combines a beveled‑up single‑bevel edge with a round steel handle for fingertip control. The sterile, disposable format delivers the sharp, predictable entry geometry that MICS techniques require, without relying on repeated sterilization. Each blade arrives ready for immediate use, supporting case‑to‑case consistency in anterior chamber penetration.
The Akahoshi hydrodissection cannula uses a curved 27ga shaft to direct fluid behind the anterior capsule and separate the lens cortex in a controlled wave. Its curvature follows the capsular bag, giving the surgeon a predictable approach for pre‑chop and quick‑chop phaco techniques. The fine gauge keeps incision distortion to a minimum.
Extending the bend to 11mm on a 20ga shaft, this anterior chamber cannula reaches the far chamber periphery while preserving high‑flow capability. The longer bend supports access behind the iris and across the chamber through a single corneal port. Stainless construction maintains rigidity through repositioning.
Built around a larger 20ga lumen, this anterior chamber cannula supports higher‑flow irrigation when rapid chamber refill is needed. The 7mm bend reaches across the chamber while the wider bore minimizes pressure loss through the shaft. Stainless tubing holds the angle through repeat manipulation.
Carrying a 21ga lumen with a 4mm bend‑to‑tip, this anterior chamber cannula is sized for moderate‑flow irrigation and short‑reach work just beneath the corneal incision. The shorter bend keeps the outlet close to the wound, suited to wound hydration and edge sealing after phacoemulsification.
This straight 22ga anterior chamber cannula is supplied in non‑sterile configuration for institutional preparation and bulk sterilization prior to use. The broader gauge supports adequate irrigation flow for hydrodissection and cortex management, while the 38mm overall length permits reliable anterior chamber access. Pre‑sterilization sizing accommodates various surgical workflows.
This straight anterior chamber cannula is sized for moderate irrigation flow during hydrodissection and cortex removal in routine cataract surgery. The 23ga gauge reduces fluid turbulence compared to larger cannulas, while the 4mm bend‑to‑tip geometry optimizes access beneath clear corneal incisions. Sterile, single‑use delivery ensures consistent performance.
A 23ga lumen on this anterior chamber cannula carries the higher flow useful for viscoelastic delivery and chamber maintenance, while a 7mm bend‑to‑tip places the outlet where the surgeon needs it within the chamber. The intermediate gauge balances flow capacity with atraumatic incision passage.
This extended‑length 23ga anterior chamber cannula provides deeper reach in cases requiring enhanced posterior chamber access during complex cataract procedures. The straight geometry supports stable insertion, while the 32mm overall length (1‑1/4") extends intraocular reach compared to standard models. Single‑use sterility guarantees consistent performance.
This anterior chamber cannula combines a 25ga fine lumen with an extended 10mm bend‑to‑tip profile for deep chamber irrigation during complex cases. The modest gauge supports adequate flow while preserving precision, and the lengthened bend geometry enhances access to posterior chamber regions. Sterile, single‑use format guarantees reliable performance.
This straight anterior chamber cannula with modest 5mm bend provides stable access for routine anterior chamber irrigation and gentle cortex aspiration. The 25ga fine gauge reduces flow turbulence and supports precise control, while the minimal bend maintains a stable insertion angle. Single‑use sterility ensures consistent edge sharpness across all procedures.
The 25ga anterior chamber cannula with a 7mm bend balances moderate flow with extended reach across the chamber. The mid‑gauge lumen supports viscoelastic injection and irrigation without the turbulence of larger‑bore tubing, while the 7mm bend places the working tip well beyond the wound entry. Stainless tubing retains the angle through repeat manipulation.
This 26ga anterior chamber cannula is engineered for ultra‑fine irrigation during minimally invasive cataract procedures and anterior chamber manipulation. The 8mm bend‑to‑tip distance provides controlled access without excessive reach, while the 12mm overall length permits precise intraocular positioning. Single‑use sterility ensures the cannula remains uniformly sharp and contaminant‑free.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.