Your cart is empty!
Select a category below to browse instruments
Categories
Browse Instruments
This Barnhill adenoid curette, size 1, incorporates a 15×16mm curved head with a 12mm cutting edge and a Bruns‑style handle across a 222mm length for efficient tissue curettage.
Features & Benefits
This Barnhill adenoid curette, size 2, features a 17×18mm curved head with a 15mm cutting edge and a Bruns‑style handle for controlled removal of larger adenoid tissue volumes.
This Barnhill adenoid curette, size 0, uses a 13×14mm curved head with a 10mm cutting edge and a Bruns‑style handle with a 222mm overall length for controlled adenoid removal.
Barnhill adenoid curettes Size 3 deliver controlled removal of hypertrophied adenoid tissue during routine tonsillectomy and adenoidectomy procedures in adolescent and adult patients. The 19 × 20mm curved head with 16mm cutting edge provides adequate working geometry for efficient tissue debulking. Bruns-style handle offers familiar ergonomic grip during controlled nasopharyngeal dissection.
This House angled double‑ended curette features 2mm × 2.5mm and 2.25mm × 3mm cups with a 35‑degree angle, serrations, and a flat handle across a 180mm length for enhanced curettage control.
Built straight rather than angled, this double‑ended House curette carries matched 1.5mm cups on a slim 159mm shaft for atticotomy and stapedial work where a smaller working face is needed. The compact cups thin bone in controlled passes without forcing the working angle.
This Buck ear curette, size 0, features an angled blunt head with a 1.5mm outer diameter and a 150mm length for controlled cerumen removal.
The Freimuth ear curette with 2.3 × 4.5mm serrated loop is designed for controlled removal of canal granulation tissue and bony disease during chronic otitis media and canal exostosis procedures. The serrated loop geometry grips diseased bone without slipping, improving removal efficiency. The 160mm length supports controlled access through the aural canal.
The Barnhill adenoid curette size 4 removes adenoid hypertrophy and lymphoid tissue during pharyngeal surgery. Its 21 × 22mm curved head with 18mm cutting edge efficiently evacuates disease from the nasopharynx. The Bruns style handle and 222mm length support extended reach and control.
Sized at the smallest end of the range, this size 00 Buck ear curette carries a 1mm outer diameter angled blunt head on a 150mm shaft. The angled head reaches the medial canal where cerumen and squamous debris collect against the tympanic membrane, while the blunt edge protects skin and drum. Stainless steel construction holds the slender head geometry through repeat office and OR use.
The double‑ended House stapes curette carries slightly angled oval cups at 3 × 1.7mm and 3 × 1.9mm for graded scraping of bone and stapes superstructure during otosclerosis surgery. The 181mm overall length keeps the surgeon's hand clear of the operative microscope while preserving fine tactile feedback.
This antrum curette features a 1.5mm × 6mm cup with a 190mm overall length for controlled removal of antral tissue.
The large Shapleigh curette pairs an extra‑delicate 2mm serrated loop with a flexible shaft and flat handle, scaling the small variant up for slightly larger ear canal cerumen work. The serrated loop bites without slipping, and the flexible shaft conforms to canal curvature.
The adenoid curette (reverse curved, size 0) is a compact instrument designed for gentle adenoid tissue removal in pediatric patients with smaller nasopharyngeal anatomy. The size 0 cup and reverse curvature allow controlled adenoid removal without nasopharyngeal wall trauma. The blunt geometry is particularly suited for small children where mucosal integrity is paramount.
This reverse curved adenoid curette size 1 provides controlled adenoid tissue removal during pediatric pharyngeal surgery. The smaller design suits young patients with narrower nasopharyngeal anatomy. Reverse curvature geometry enables pull-stroke evacuation of adenoid tissue.
The reverse-curved adenoid curette is engineered for controlled adenoid tissue removal during transoral adenoidectomy. The standard curve design follows the pharyngeal contour, enabling efficient stripping of adenoid tissue from the nasopharynx. Size 2 accommodates pediatric and smaller adult nasopharyngeal anatomy.
Reverse-curved adenoid curettes Size 3 provide alternative tissue-removal approaches during adenoidectomy, accommodating varied surgical strategies and anatomical presentations. The reverse geometry enables effective stroking from alternate nasopharyngeal angles, particularly useful in difficult cases or posterior adenoid extension. Curved design reduces inadvertent mucosal trauma during controlled tissue separation.
A Size 4 reverse-curved adenoid curette designed for larger nasopharyngeal anatomy and efficient adenoid removal in adult and adolescent patients. The standard curve follows the contour of the adenoid fossa, supporting controlled tissue stripping without mucosal trauma. Stainless steel ensures lasting clinical durability.
The antrum curette with straight configuration and 10 × 3mm cup tip is designed for controlled maxillary sinus curettage during Caldwell-Luc and endoscopic sinus procedures. The large cup surface spreads force across antral mucosa, reducing perforation risk during disease removal. The 191mm length provides secure control in deep antral spaces.
The antrum curette (7mm × 11mm oval cup, gently curved, flat handle, 190mm) removes inflammatory tissue and bone dust from the maxillary antrum. Its oval cup shape fits the antral anatomy while the gentle curve permits controlled scraping strokes. The 190mm length facilitates access to posterior and superior antral regions.
This large antrum curette features an oblong cup measuring 3.7 × 9.5mm with a straight shank, designed for removing diseased mucosa and bone debris from the maxillary antrum during antrostomy or sinus clearance procedures. The oblong shape allows sweep‑and‑catch motion while conforming to antral walls without perforation.
Barnhill adenoid curettes Size 1 deliver controlled adenoid tissue removal with monopolar electrosurgical capability enabling hemostatic debulking during pediatric adenoidectomy. The compact size accommodates narrow nasopharyngeal anatomy in young children. Electrosurgical integration reduces blood loss while maintaining controlled tissue separation during adenoid debulking.
Barnhill adenoid curettes Size 2 provide intermediate-capacity tissue removal during pediatric and early adolescent adenoidectomy procedures. Monopolar electrosurgical design enables hemostatic control during adenoid debulking in mixed pediatric-adult nasopharyngeal anatomy. Graduated sizing across the Barnhill series allows procedure-matched instrument selection.
The Barnhill adenoid curette (size 3, monopolar) combines electrical conductivity for hemostatic adenoid tissue removal with a size 3 cup geometry suited for adolescent and adult adenoid hypertrophy. The monopolar design permits integrated electrosurgery during adenoid bed hemostasis following mechanical removal. The blunt cup design prevents nasopharyngeal wall perforation during adenoid curettage.
Barnhill adenoid curettes Size 4 are the largest in the graduated curette series, designed for efficient adenoid tissue removal in adult cases with significant adenoid hypertrophy. Monopolar electrosurgical design enables hemostatic control during extensive nasopharyngeal tissue debulking. Robust construction tolerates the mechanical demands of adult adenoidectomy procedures.
This Beckman adenoid curette (Size 5, 14.5mm) delivers focused tissue removal during pediatric adenoidectomy. The 200mm overall length provides mechanical advantage while the 14.5mm cup diameter accommodates the adenoid bed dimensions. The straight design prevents inadvertent contact with the soft palate.
The Beckman adenoid curette (Size 6, 17.5mm) offers a larger cup for adenoid removal in older children and young adolescents. The 200mm length provides ergonomic control while the 17.5mm diameter cup accommodates larger adenoid tissue volumes. The straight geometry prevents palatal contact during intraoperative manipulation.
This Buck ear curette, size 0, uses a blunt angled head with a 2.3mm outer diameter and a 150mm length for controlled cerumen removal.
The Buck ear curette with angled head and blunt tip (Size 1, 2mm) provides atraumatic removal of canal skin lesions, debris, and cerumen impactions during otologic surgery. The angled working head accesses canal walls without requiring excessive manipulation. At 152mm overall length, the curette delivers controlled leverage while the 2mm blunt tip prevents accidental tympanic membrane trauma.
The Buck ear curette with angled head and blunt tip (Size 2, 2.5mm) accommodates larger debris and cerumen removal during otologic procedures while maintaining atraumatic technique. The 2.5mm working diameter provides expanded surface area for efficient instrumentation.
Our sales specialists are available Monday through Friday, 9am to 5pm EST.